The necessary clearance from left to right.
Yoilet clearance from back wall ada bathrooms.
Clearance around a water closet shall be 60 inches 1525 mm minimum measured perpendicular from the side wall and 56 inches 1420 mm minimum measured perpendicular from the rear wall.
In both alternate stalls the centerline of the water closet is 18 inches 455 mm from a side wall.
A clear circle of at least 60 inches around the side wall and 56 inches from the rear wall to allow a wheelchair to turn the door cannot swing into the minimum required area for wheelchair accessible toilet compartments.
A person has 9 vertical clearance for their feet and 27 vertical clearance for their knees.
And it s pretty important to get these measurements right just imagine the look on your wife s face or husband after you accidentally set the toilet.
This guide explains requirements in the ada standards for clear floor or ground space and turning space.
In both alternate stalls the grab bars along the sides of the water closets shall extend at least 54 inches 1370 mm from the back wall and shall have one end no farther than 12 inches 305 mm from the back wall.
The americans with disabilities act ada of 1990 includes specific guidelines for the construction of accessible or ada compliant bathrooms.
How much space to leave in front of the bowl.
Clearances around toilets and water closets wcs can be measured from the face of the fixture or from its center line and are used to best service the toilet user.
Generally this will ensure enough clearance room in front of the toilet.
Clearances are required at accessible elements fixtures and controls so that people with disabilities including those who use wheelchairs can approach and use them.
They can also serve as a general guide for safe user friendly accessible design when ada compliance is not required.
Where to put the cold water supply line.
Clearances around water closets and in toilet compartments shall comply with 604 3.
A toilet seat height of 17 19 inches.
The center line of the toilet must be between 16 and 18 inches from the side wall.
For wheelchair accessibility the center line of the toilet must be between 16 18 405 455 mm from the wall.
The distance to set the toilet flange from the back wall.
The distances to the finished side.
The back wall clearance which is the distance to the finished back wall is usually 12 inches but it can also be 10 or 14 inches depending in the toilet.
These design requirements must be met for most public and commercial bathrooms.
Try to place the toilet facing an open wall or door if possible rather than a fixture.
Accessories such as toilet paper dispensers should be within.